Electrical Load Calculator for Dubai Homes

Calculate total wattage, current draw (amps), recommended DEWA breaker size, and estimated monthly electricity bill. Plan your circuit safely — no more tripping breakers or undersized wiring.

220V UAE standardDEWA-compliant breaker sizesIncludes 25% safety factor
Your Appliances
Add the appliances on this circuit. Pick from common presets or enter custom wattage.
Load Summary
Live calculation · 220V single phase (UAE standard)

Total connected load

2,072 W

= 2.07 kW

Current draw

9.4 A

Daily usage

19.6 kWh

Recommended breaker size

16 A

MCB at 125% of calculated load (11.8A) — next standard size up

Monthly usage

589 kWh

Est. DEWA bill

AED 224

Important

This calculator gives an estimate for residential planning. Actual breaker sizing must follow DEWA regulations and UAE electrical code. Always have a licensed electrician verify before installation.

Standard DEWA Breaker Sizes
6A
10A
16A
20A
25A
32A
40A
50A
63A

Highlighted = recommended for your load

How the Calculator Works

Designed for UAE 220V single-phase residential installations. Follows DEWA regulations and UAE electrical code.

1. Add Appliances

Pick from common presets (ACs, lights, kitchen appliances) or enter custom wattage. Set quantity and hours-per-day for each appliance.

2. Calculate Load

Total watts = sum of (appliance watts × quantity). Current draw (amps) = total watts ÷ 220V. We apply a 25% safety factor for breaker sizing.

3. Get Breaker Size

We round up to the next standard DEWA breaker size (6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A) — and estimate your monthly DEWA bill from usage hours.